Upsmon For Mac

Posted on  by 



UPS
Model
MAC-1000
MAC-1500
MAC-2000
MAC-3000
MAC-6000
MAC-10000
Capacity(VA)
1000 VA
1500 VA
2000 VA
3000 VA
6000 VA
10000 VA
Capacity(Watts)
1000 W
1500 W
2000 W
3000 W
6000 W
10000 W
Form
Tower Type
Phase
Single Phase
Energy Saving
Yes - ECO Mode Efficiency > 94%

INPUT
Voltage
208 / 220 / 230 / 240 Vac
Voltage Range
120 - 276 Vac, < 25% Load
140 - 276 Vac, < 50% Load
160 - 276 Vac, < 75% Load
180 - 276 Vac, < 100% Load
Frequency Range
50 / 60 Hz (Auto Sensing)
Power Factor
> 0.97
Cold Start
Yes

OUTPUT
Rated Power Factor
1.0
Waveform
Pure Sine Wave
Voltage
208 / 220 / 230 / 240 Vac ± 2%
Frequency
50 / 60 Hz ± 0.25 Hz
Transfer Time
0 ms
Harmonic Distortion
≦ 2.5% THD at Linear Load
Crest Factor
3 : 1
EPO Function
Option
Output Receptacle Option

PROTECTION
Overload Line Mode
105% - 120% for 30 seconds
121% - 150% for 10 seconds
Battery Mode
101% - 109% for 10 seconds
110% - 120% for 3 seconds
Surge Protection
IEC 61000-4-5 Level 3
Bypass
Internal Bypass(Automatic and Manual)
Short Circuit Protection
UPS Output Cut Off Immediately

BATTERY
Type
12V 9Ah
12V 7Ah
12V 7Ah
12V 9Ah
12V 7Ah
12V 9Ah
Quantity
2
4
6
6
20
20
Sealed, Maintenance Free
YES
Typical Recharge Time
4 Hr to 90%
External Battery Module
Option
External Battery Connector
Option

ENVIRONMENT
Operating Humidity
0~90% RH at 0~40°C(Non-condensing)
Audible Noise
Less than 40 dB
Less than 55 dB
Altitude
< 2000m
Heat Dissipation (BTU/h)
342
512
683
1024
2047
3412

MANAGEMENT & COMMUNICATION
LCD Control Panel
YES
Communication Port
RS232, USB(B-type)
SNMP Slot
Option
Audible Alarms
YES

PHYSICAL
Dimensions(WxDxH)(mm)
144 x 357 x 228
191 x 406 x 327
257 x 590 x 570
Weights(Kgs)
10.4
16.4
20.3
22.9
86
95
Shipping Dimensions(mm)
249 x 448 x 359
292 x 500 x 455
257 x 590 x 700
Shipping Weights(Kgs)
11.5
18.4
22.3
24.9
106
115

Upsmon Mac

Software

Upsmon For Macbook Air

* While 208V output, capacity will derated to 90% * Specifications are subject to change without further notice * Specifications are for reference, actual information should be based on real productForMac
  • Iv. Contents UPSMON User Manual 2. Uninstall procedure for UNIX 74 3. Uninstall procedure for Novell Netware 74 4. Uninstall procedure for Mac OS X 74 VIII. Configuration for expert users 75 1. Manual changes of the UPSMON.INI parameters 75 2. Console execution of Upsagent 75 IX. Communication port specifications 77.
  • I have an APC UPS connected to my synology nas and I am trying to get my mac (10.13) to connect to the 'network ups' of synology. So far I've been trying to follow this guide: https://community.n.
  • MAC series added Diagram LCD Display and Six sections Fan Regulation for information indication directly and operating environment quietly, upgrades user experience and working quality. POWERCOM MAC series combine with high tech design and better model performance is the best choice for high-class computer, data center and server.

Upsmon For Macbook Pro

Upsmon for mac os

1b) UPS shuts down Mac, and just before the last shutdown item from Apple which hopefully triggers the nvram clock chip (or whichever chip causes the auto-startup), a specially written shutdown program halts the system horribly. Think system freeze.





Coments are closed